Warning: Copy the PLC-program before deleting the PLC or use the original project (one that was not uploaded by a PLC) to update the web server’s user management and to download the changed configurationĪs a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. The PLC must be deleted and reconfigured with a new project.

  • If a new TIA-Portal version is not available, updating the web server’s user configuration is not effective.
  • If unintentional, unauthenticated access is possible, the web server’s user configuration needs to be removed and reconfigured using TIA-Portal v16 Update 5 or later, or v17 Update 2 or later related ET200 CPUs and SIPLUS variants), validate web server permissions for unauthenticated users by directly accessing the web server in an unauthenticated manner.

    siemens step 5 v7.2 software

    Whenever changes of the web server’s user configuration are performed with one of the affected versions for S7-1200 or S7-1500 CPUs (incl.Siemens has identified the following specific workarounds and mitigations users can apply to reduce the risk:

    siemens step 5 v7.2 software

  • SIMATIC STEP 7 (TIA Portal) v17: Update to v17 Update 2 or later.
  • SIMATIC STEP 7 (TIA Portal) v16: Update to v16 Update 5 or later.
  • SIMATIC STEP 7 (TIA Portal) v15: Currently no fix is planned.
  • Siemens recommends updating their software to the latest version: Siemens reported this vulnerability to CISA.
  • CRITICAL INFRASTRUCTURE SECTORS: Multiple Sectors.
  • A CVSS v3 base score of 6.4 has been calculated the CVSS vector string is ( AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:L/A:L). The attacker needs to have direct access to the impacted web server.ĬVE-2021-42029 has been assigned to this vulnerability.
  • SIMATIC STEP 7 (TIA Portal) v17: All versions prior to v17 Update 2ģ.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER ACCESS CONTROL CWE-284Īn attacker could achieve privilege escalation on the web server of certain devices due to an improper access control vulnerability in the engineering system software.
  • SIMATIC STEP 7 (TIA Portal) v16: All versions prior to v16 Update 5.
  • SIMATIC STEP 7 (TIA Portal) v15: All versions.
  • The following Siemens products are affected:

    siemens step 5 v7.2 software

    Successful exploitation of this vulnerability could allow an attacker to achieve privilege escalation on the web server of certain devices configured by SIMATIC STEP 7 (TIA Portal) due to incorrect handling of the webserver’s user management configuration during downloading.